上海利海电机有限公司
主营产品:台湾利明减速机,台湾宇鑫减速机,台湾富田电机,台湾东伟庭电机,台湾高压风机
免费会员
  • 联系方式
与我联系时,请说明:
是在“化工机械网”看到的
  • 联系人:李培林
  • 电 话:0531-68824601
  • 手 机:13816946848
  • 传 真:021-64604852
  • 地 址:上海松江泗泾镇九干路168号6幢303


以下是百度推荐信息
  • 产品展示
产品名称: 韩国SPG电机模拟式调速机
产品编号: 35
产品商标:
产品规格: 台
参考价格: 面议
更新日期: 2020/5/8 9:42:43
被阅次数: 1884次
 
  • 详细说明
模拟式调速机






≥ The following functions are features of the automatic computer control.



 




(1) Power-on Status Alternating Switch (default setting is “NO”)
This mode features the following two modes to select the
running status of motor, when power is supplied.
YES
If the status is set to “RUN”before beingpowered off, it runs even though the power is supplied.
If the status is set to “STOP”before being powered off, it stops even though the power is supplied.
NO
Regardless of the status before being powered off, whether it might be “RUN”or “STOP”, it stops when the power is supplied.
Please set up as “NO”before ordinary use. It may help
prevent an unexpected operation incurred by restoration after a
blackout or when power is supplied again.

When using it set to “YES”
(Please use in the SET mode)

it is possible to remotely control its running or stopping by manipulating the RUN/STOP key as it is powered “on”or “off”
Setting
1. Please set the Power-on Status Alternating Switch as “YES”.
2. Please click the RUN/STOP key once as the power is supplied.
(To make sure the perception of the operation of “YES”)

Cautions
1. It takes about 2 seconds of resetting time from power being supplied until the commencement of operation.
2. The operation can be delayed when it is used for extended period of time with the RUN/STOP key. Then, it indicates “RUN” and “STOP” simultaneously. When this occurs, the operation can be restored to normal condition by alternating to “NO”, turning it off for more than 1 second, and restoring the power supply, provided that the function of “YES”is still available.

(2) Restoration after a blackout
The operation depends on the selected status prior to the blackout by the Power-on Status Alternating Switch in cases such as to detect an instant blackout or to restore the power supply.
(3) Reset time
It requires about 2 seconds of resetting time when the power is supplied. And in this period, no digital indication is made..

After the power is supplied, please use the keys to change the status after the digital indications are completely made.
And if the status is set to “RUN”before turning it off when the Power-On Status Alternating Switch is set as “YES”, it starts the operation about 2 seconds after the power is supplied. It also takes about 2 seconds in the case of an instant blackout.

(4) Automatic alternation of frequency
Set as 1400~1800 rpm (multiplication ratio of 1) in the region of 60 Hz, it becomes 1500 rpm in the region of 50 Hz.
Set as 1500 rpm in the region of 50 Hz, however, it remains 1500 rpm even in the region of 60 Hz.
(5) Trouble indications
When any trouble occurs, “RUN”and “STOP”are simultaneously indicated.
Some cases show that it may be restored to the normal condition when the power is supplied again (provided that the setting values become the default ones).
If it simultaneously indicates “RUN”and “STOP”even after the power is restored, you must consider a malfunctions of the internal circuits. Please inform the technology institute of the Company.
If the operation lifespan of the RUN/STOP key expires with the Power-on Status Alternating Switch set to “YES”, please refer to the countermeasures of Clause 7.1.

(6) Thermal Protector (Automatic Return Type)
As protection against overheating, a thermal protector is built into the motor, according to the type of the motor.
As the motor becomes overheated, the thermal protector is actuated to stop the operation.
And when the motor is cooled later, the thermal protector returns, and it runs again without manipulation for “RUN”.

(7) Tests on dielectric strength and impulse voltage
On the power plug, please cut off the two wires outside of the motor ground wire for performing tests on dielectric strength between the line earths, on impulse internal pressure, and on insulation resistance, as it is installed on the control plate.

 
 


 
 
(1) Selection of rotary direction
1) For continuous one-way operation
To reverse the rotary direction at conveying parts such as the gear head, please change the connections so that the positions of the connectors  COM and  CW attached to the side of the controller are connected to  COM and 
CCW.
Please be sure that the power wires are connected to ㄧ AC and ㄨ AC in any case. For this, please turn it off before changing and connecting the wires
2) For clockwise and counterclockwise operation
Please install the switches for power supply (SW1) and for changing the rotary directions (SW2) to change the direction of revolution.
Instant direction-changing revolution is impossible. Please turn off the switch for power supply (SW1) first, and then exchange the switch (SW2) after the motor is stopped completely.
Switch No.
Switch Contact Capacity
SW1
AC 125V or AC 250V, more than *
SW2
AC 125V or AC 250V, more than *


(2) Mounting procedure


1) Make a rectangular hole on the mounting panel.
2) Insert the controller body combined with the front cover into the rectangular hole and use M4 screws and nuts to fix.






 
 
(1) RATIO MODE
This mode indicates the actual speed by multiplying the revolution speed by the magnification, where it is possible to calculate the revolution speed of the output axis of the gear head and the
returning speed of the conveyor belt.
1) Set value of Gear Ratio (for indication conforming to the revolution speed of the output axis of the gear head) ex); since the default gear ratio of the
Company is in memory, please use the ¤ and ¢ keys for
selection.
1.000£3£ˇ£100ˇ£202ˇ£1000ˇ£2515
Please refer to page 144: “6. Table of Gear Ratio”

2)Set value of Multiple Magnification (for indication conforming to the returning speed of the conveyor belt) ex); since the multiple magnification is set from 0.005 to 0.995, please use the ¤ and ¢ keys for selection.
1.000£0.995£ˇ£0.015£0.010£0.005 (intervals of 0.005)

(2) SET MODE
This mode sets up the revolution speed, using the ¤ and ¢ keys.
If the indicated magnification is 1.000
The selection unit is 10 rpm.
ex)Power frequency 50Hz:90£100£110£ˇ£1400£1500rpm
     Power frequency 60Hz:90£100£110£ˇ£1400£ˇ£1700£1800rpm If the indicated

If the indicated magnification is other than 1.000
It is indicated according to the indicated magnification setting in “RATIO mode”and the gear ratio setting, which can be selected by using the ¤ and ¢ keys..
Ex) Set value of gear ratio = 3
Selection with a unit of 10±3 rpm is possible. The value is indicated down to one decimal place.
·Power frequency 50Hz:29.9£33.3£36.6£ˇ£466.6£500.0rpm
·Power frequency 60Hz:29.9£33.3£36.6£ˇ£466.6£ˇ£566.6£600.0rpm

Ex) Set value of multiple magnification = 0.500
Selection with a unit of 10】0.500 is possible. The value is indicated down to one decimal place.
·Power frequency 50Hz:45.0£50.0£55.0£ˇ£700.0£750.0rpm
·Power frequency 60Hz:45.0£50.0£55.0£ˇ£700.0£ˇ£850.0£900.0rpm

(3) REAL MODE
The REAL mode indicates the actual revolution speed of motor by multiplying by the indicated magnification. The selection unit is 5 rpm “for the indicated magnification of 1.000”.
Ex) 0£5£10£ˇ£90£95£100£ˇ£1400£ˇ£1700rpm
Indicates according to the indicated magnification setting of RATIO mode “for the indicated magnification is other than 1.000”.


Ex) Set value of multiple magnification = 0.500
Selection with a unit of 5】0.500 is possible. The value is indicated down to one decimal place.
0£1.6£ˇ£29.9£31.6£33.3£ˇ£466.6£ˇ£566.6rpm

ex)Set value of multiple magnification = 0.500
Selection with a unit of 5】0.500 is possible. The value is
indicated down to one decimal place.
0£1.6£...£29.9£31.6£33.3£...£466.6£...£566.6rpm
[NOTE]

“rpm”is indicated only for the indicated magnifications exceeding 1.000
(including 1.000).
Nothing is indicated when the indicated magnification is less than 1.000.


(4) S/R MODE
This mode sets up the Slow Run time, using the ¤ and ¢ keys.
The selection unit is 0.1 second, of which the maximum range is to 30 seconds.
0£0.1£ˇ£0.2£0.3£0.4£ˇ£29.9£30.0 sec.

(5) S/S MODE
This mode sets up the Slow Stop time, using the¤ and ¢ keys.
The selection unit is 0.1 second, of which the maximum range is to 30 seconds.
0£0.1£ˇ£0.2£0.3£0.4£ˇ£29.9£30.0 sec.



(6) Power-On Status Setup mode
As the Power-On Status Alternating Switch, this mode enables selections of operation as the power is supplied.

1) If the mode is set as “YES”
When the power is supplied, it repeats the same operation as that before it was powered off.
Before being powered off
After being powered off
"RUN" state
Starting (about 2sec, later)
"STOP" state
Stop

2) If the mode is set as “NO”
When the power is supplied, it is stop regardless of the previous state before being powered off. Please use RUN/STOP key for re-operation.
Before being powered off
After being powered off
"RUN" state
Stop
"STOP" state
Stop

    





 
 
Since there may be slight differences between the nominal gear ratios and the actual ones, please refer to the table for equipment setup.

Nominal
gear ratio
Actual gear ratio
Inter-decimal
GEAD HEAD
60/ 6W
70/ 15W
80/15W
80/ 25W
90/ 40W
90/ 60W
90/ 90W
3
3.00
3.00
3.00
3.00
3.00
3.00
3.00
10
3.6
3.60
3.59
3.57
3.57
3.60
3.60
3.60
5
5.00
5.00
5.00
5.00
5.00
5.04
5.04
6
6.00
6.00
6.00
6.00
6.00
6.00
6.00
7.5
7.50
7.50
7.50
7.50
7.50
7.50
7.50
9
9.00
9.00
9.00
9.00
9.00
9.00
9.00
10
10.00
10.29
10.00
10.00
10.00
10.00
10.00
12.5
12.50
12.14
12.50
12.50
12.50
12.50
12.50
15
15.00
15.00
15.00
15.00
15.00
15.00
15.00
18
18.00
17.92
18.08
18.08
17.67
18.00
18.00
20
19.90
20.00
20.00
20.00
20.00
20.19
20.19
25
25.06
24.80
25.00
25.00
24.73
25.00
25.00
30
30.25
30.00
30.00
30.00
30.00
30.00
30.00
36
36.30
36.00
36.00
36.00
36.00
36.00
36.00
40
40.80
40.36
40.11
40.11
40.36
39.68
39.68
50
50.00
50.00
50.00
50.00
50.00
50.00
50.00
60
60.00
60.00
60.00
60.00
60.00
60.00
60.00
75
75.00
75.00
75.00
75.00
75.00
75.00
75.00
90
90.00
90.67
90.00
90.00
90.00
90.00
90.00
100
100.0
100.0
100.0
100.0
100.0
100.0
100.0
120
120.0
118.0
120.0
120.0
120.0
120.0
120.0
150
150.0
154.0
150.0
150.0
150.0
149.9
149.9
180
180.0
181.2
180.0
180.0
180.0
179.8
179.2
200
198.9
194.8
200.0
200.0
201.8
197.2
197.2
250
251.5
-
-
-
-
-
-

If the nominal gear ratio is 1/200 for 40W, the actual ratio is 1/201.8, and thus the ratio shall be set up as 201.8..





 
 

When any trouble occurs, please check and take measures according to the
following tables. If the cause is unclear or it is thought to have mechanical trouble,
please contact the buyer or the technology institute of the Company.


(1) If the motor does not rotate:





(2) If the rotations are not changing:



(3 ) If abnormal heat is generated during the operation:



♂ 1. If it indicates “RUN”and “STOP”simultaneously, it is caused either by a failure of the
controller or as the operation limit of “YES”mode is reached. Please use in “NO”mode.

♂ 2. Voltage Check: Please check up the voltages of the black-white and black-gray wires with
the motor connector connected.
(Voltage doubled for 220V specifications)

♂ 3. Turn on Test
Please check up the resistance of the red-red wire with the motor connector disconnected.

♂ 4. Voltage Check
Please check up the voltage of the red-red wire with the motor connector connected.





 
 
Items Models
SUD∴IA-V12
SUD∴IB-V12
SUD∴IC-V12
SUD∴ID-V12
SUD∴IX-V12
Proper voltage
1-phase 110V
1-phase 220V
1-phase 100V
1-phase 220V
1-phase 220V - 240V
Voltage limits
【10%(against the proper voltage)
Power Frequency
60Hz
60Hz
50/60Hz
50/60Hz
50Hz
Speed control limits
60Hz : 90-1700rpm
50Hz : 90-1400rpm
Speed change rate
5%(Standard)
Speed Setup
Digital setting
Time for Slow Run/
Slow stop
0.1 ~ 30 sec
Temperaturel Iimits for use
0 ~ 40∩
Temperature limits
-10 ~ 60∩
Humidity limits
Less than 85%PH (Non condensing)





 
 



免责声明:以上信息由企业自行提供,该企业负责信息内容的真实性、准确性和合法性。化工机械网对此不承担任何保证责任。
  • 上海利海电机有限公司 版权所有
  • 电话:0531-68824601  传真:021-64604852
  • 地址:上海松江泗泾镇九干路168号6幢303  邮编:201100